{"product_id":"nano-hp15-trimix-compressor","title":"Nano HP15-TRIMIX Compressor","description":"\u003ch1\u003e\u003cspan\u003eNano HP15-TRIMIX Compressor\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan\u003eCompact. Oil-free. Water-cooled. Now with Trimix capability.\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Nano HP15-TRIMIX extends the capabilities of the Nano HP15 with an external gas inlet for compressing premixed Trimix and other compatible breathing gas mixtures with an oxygen content of up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for filling small cylinders, this compact, oil-free, water-cooled high-pressure compressor delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15 litres per minute\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e at a noise level of just \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65 dBA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA selectable inlet allows operation with either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eambient air\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ean external breathing gas supply connected through the front inflator port\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEquipped with automatic final-pressure shut-off, an hour meter and a replaceable breathing air filter cartridge, the Nano HP15-TRIMIX fills to a maximum pressure of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 bar \/ 2900 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe compressor can be operated from a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e110 V, 220 V or 12 V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e power supply. A filling hose with a quick coupling for direct connection to your Sailair cylinder is included.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cspan\u003eTwo Selectable Inlet Modes\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eAmbient Air Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe compressor draws in surrounding air and operates like the standard Nano HP15.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eExternal Gas Mode — Inflator Port\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe compressor draws premixed breathing gas from an external cylinder through the front inflator port. This allows remaining gas, \u003c\/span\u003e\u003cspan\u003eto be transferred and compressed into a receiving cylinder.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMaximum oxygen content: 40%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Nano HP15-TRIMIX compresses an existing gas mixture; it does not blend a new mixture.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cspan\u003eHow External Gas Operation Works\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eA diving regulator is connected to the supply cylinder. Its inflator hose connects to the inflator port on the front of the Nano HP15-TRIMIX, supplying gas at an intermediate pressure of approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10 bar\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe compressor’s inlet pressure regulator reduces this pressure to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2 bar\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The setting must be checked and adjusted to 2 bar if necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe gas then passes through the flow monitoring device, which must be set to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15 litres per minute\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, before entering the compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe water-cooled compressor compresses the supplied gas to a maximum pressure of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 bar \/ 2900 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and switches off automatically when the final filling pressure is reached.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore filling, set the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003einlet selector ball valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to the required source:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInflator Port:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for an external premixed breathing gas supply.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAmbient Air:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for standard air filling.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe supply cylinder and regulator must maintain the required inlet pressure and gas flow throughout filling.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cspan\u003eStandard Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOil-free, water-cooled compression\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelectable inlet: ambient air or external breathing gas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFront inflator port for connection to a regulator inflator hose\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInlet pressure regulator with a 2 bar setting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow monitoring device with a 15 l\/min setting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic final-pressure shut-off\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo safety pressure relief valves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHour meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure maintenance valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFilling hose with quick coupling\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManual drain valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplaceable breathing air filter cartridge\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature compensation table for filter cartridge service life in ambient air operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating instructions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVent valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnection cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Data\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eNano HP15-TRIMIX\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 V \/ 220 V \/ 12 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e350 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum current at 12 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNoise level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum filling pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e200 bar \/ 2900 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilling rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 l\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions, L × W × H\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 × 18.5 × 32 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWater-cooled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompression\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOil-free\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInlet selection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient air \/ front inflator port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal supply intermediate pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 10 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRegulated inlet pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlow monitoring setting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 l\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum oxygen content of supplied gas\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e40%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cspan\u003eNano HP15 Filter Cartridge — Order No. 1998\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eFiltration for Ambient Air Operation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe replaceable Nano HP15 filter cartridge removes moisture and contaminants from compressed air during ambient air operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts capacity and service life depend on ambient temperature and operating conditions. The tables below support maintenance planning for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAmbient Air Mode only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThese filter capacity and service life tables do not apply to Trimix operation using an external gas supply, as the supplied gas must already meet breathing gas quality requirements before entering the compressor.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCylinder Filling Capacity — Ambient Air Mode Only\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eMinimum number of cylinder fillings (±5%), depending on ambient temperature and cylinder size:\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eAmbient Temperature (°C)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003e1 L\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003e3 L\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003e7 L\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003e10 L\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003e12 L\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e10°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e139\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e15°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e104\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e34\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e20°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e79\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e62\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e30°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e44\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e35°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Performance and Service Life — Ambient Air Mode Only\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eAmbient Temperature (°C)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eFinal Separation Temperature (°C)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHumidity Content (g\/m³)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eProcessable Air Volume Va (m³ at 200 bar)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eMinimum Filter Life (hours ±5%)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e10°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14–18\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12–15.4\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50–38\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e34\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e15°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19–23\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.3–20.6\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36–29\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e20°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24–28\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.8–27.2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e27–22\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29–33\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.8–34.6\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21–17\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e30°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e34–39\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e36.6–48.9\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16–12\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e35°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40–44\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51.1–63.6\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11–9\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45–49\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65.0–80.4\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9–7\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eFilter Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eEfficient removal of moisture and contaminants\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature-dependent service life for maintenance planning\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplaceable cartridge for straightforward servicing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for high-pressure breathing air applications\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eMaintenance Notes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFilter performance and service life in ambient air operation depend on temperature and operating conditions. Always use original NRC filter cartridges and follow the operating instructions and recommended maintenance intervals.\u003c\/span\u003e\u003c\/p\u003e","brand":"NRC International GmbH","offers":[{"title":"Default Title","offer_id":54935759683907,"sku":"1995-15-TX","price":1790.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/1128\/9565\/files\/NANO_HP_15_TRIMIX.jpg?v=1792352768","url":"https:\/\/nrc-international.com\/products\/nano-hp15-trimix-compressor","provider":"NRC International GmbH","version":"1.0","type":"link"}